Envoy 1-4 Zone Conventional Fire Alarm Control Panels Specifications Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
2
EST3
Network
S
R
S
I
S
I
S
I
F
F
MM
CC
CC
CC
MM
MM
CT
CT
J
J
SSSS
S
J
JJ
S
S
S
SS
S
S
S
S
SS
SS
S
S
S
S
SS
S
J
CR
CR
CR
F
J
F
F
F
2Tw.Pr.
1 Tw/Sh Pr.
2Tw.Pr.
1 Tw/Sh Pr.
1 Tw/Sh Pr.
1 Pr & 2 Tw/Sh Pr.
1 Pr &
2 Tw/Sh Pr.
1 Tw/Sh Pr.
1 Tw/Sh Pr.
1 Pr &
2 Tw/Sh Pr.
1 Pr
2Tw.Pr
2 Pr.
2Tw.Pr.
2 Pr.
2 Pr.
1 Pr.
2 Pr.
2 Pr.
2Tw.Pr.
1 Pr.
To next EST3 remote
floor panel
2 Pr.
3rd FLOOR
2nd FLOOR
Primary
Power
Source
4th FLOOR
Network
control,
audio,
& telephone
WATERFLOW
SWITCH
ELEVATOR
CAPTURE
HVAC CONTROL
HVAC
CONTROL
HVAC MONITOR
HVAC
MONITOR
FIRE
DAMPER
WATER
LEVEL
MONITOR
CRITICAL PROCESS
MONITOR
SPRINKLER
SUPERVISORY SWITCH
EST3 Remote
Floor Panel
(Node)
J
F
CRC
CRC
CRC
CRC
KPDISP
CRC
DOOR
DOOR
DOOR
DOOR
DOOR
CRC
CRC
CRC
CRC
CRC
DOOR
SECURITY
INPUTS
SECURITY
INPUTS
SECURITY
INPUTS
DOOR
DOOR
DOOR
SECURITY
INPUTS
DOOR
MM
J
J
EDWARDS SYSTEMSTECHNOLOGY
S
S
R
S
I
S
I
CC
CC
MM
J
J
SSSS
S
SS
S
S
S
S
S
SS
SS
S S
S
S
S
S
SS
S
J
CR
F
J
F
F
F
1 Tw/Sh Pr.
1 Tw/Sh Pr.
1 Pr &
2 Tw/Sh Pr.
1 Pr &
2 Tw/Sh Pr.
2 Pr.
2 Pr.
2 Pr.
2Tw.Pr.
1 Pr.
2Tw.Pr.
1 Pr.
2 Pr.
GROUND FLOOR
Primary
Power
Source
1st FLOOR
HVAC
CONTROL
HVAC
MONITOR
FIRE
DAMPER
WATER
LEVEL
MONITOR
J
F
MM
J
J
EDWARDS SYSTEMSTECHNOLOGY
CPU w/display, power supply & booster, dual loop module,
audio source module w/master firefighter's telephone, 2 amplifiers, & batteries
Printer
SEC
SEC
SEC
SEC
SEC
SECURITY
INPUTS
CPU,
power supply
& booster,
dual loop
module
3 amplifiers,
& batteries
KPDISP
MD
MD
MD
MD
TELCO
Access Control Data Base
Central Monitoring Station
Paging Company
Survival of
the fittest
Typical EST3 Wiring
with Security, Access Control,
Emergency Voice/Alarm
and Firefighter's Telephones
Multiplex fire, security, and access control
Whether for fire alarm only, or for total life
safety protection including security and
access control, the EST3 network is the most
survivable system available.
EST3 uses distributed database technol-
ogy, designed to survive the rigors of fire and
firefighting. In Class B configuration a single
break on the network wiring will isolate the
system into two groups of one or more nodes.
Each group of nodes continues functioning
as a peer-to-peer network, working with
their combined databases.
In Class A configurations a single break or
short on the network wiring causes the
system to isolate the fault. Network commu-
nication continues uninterrupted. If multiple
faults occur, the network re-configures into
multiple networks. This means a system
continues to respond to activations from
every node that can transmit and receive
network messages. Local responses always
execute because the local database resides
at each node.
Exceptional survivability extends to every
EST3 function, including security and access
control. These devices (highlighted in yellow)
reside on the network alongside fire alarm
components. They share wiring, power sources
and the inherent stability of a fire alarm
network engineered to meet standards far
beyond those of ordinary security systems.
Yellow denotes security and access control components
LEGEND
Page
Manual Pull Station 34
Smoke detector with relay base 26
Smoke detector with isolator base 26
Smoke detector with standard base 26
Motion detector 27
Combination speaker/strobe 39
Firefighter’s telephone 42
Security module 33
Keypad Display 15
Card Reader Controller 16
Signal module 30
Control relay module 30
Input module 29
Monitor module 31
End-of-line resistor
Junction box
S
R
S
I
MM
CC
CT
S
CR
F
CRC
J
SEC
KPDISP
MD
EST3
Network
Page view 7